Setting Up an ESD-Safe Workstation You need the following materials to set up an ESD-safe workstation: • Conductive workbench mat, with grounding cord • Wriststrap, with built-in 1-megohm resistor and ground cord • Equipment grounding cord, with alligator clips • Ground/polarity tester Setup Procedure 1. Remove all ESD hazards from the area. Nonconductive materials (see rule 5 under ESD Prevention Rules) cannot be grounded. Such materials retain charges for hours and even days. 2. Use a ground/polarity tester to verify proper grounding of the power outlet. If the outlet is wired incorrectly, most testers show a light pattern that matches a code given on the tester. If the tester does not verify proper grounding, move to another outlet that is safe. 3. Connect the grounding cord of the workbench mat to ground. 4. Use a wriststrap grounding cord. Fasten it to the workbench mat and to the wriststrap. The wriststrap should touch your skin. You need the continuous grounding provided by a grounding wriststrap. 5. Finally, ground the equipment you are working on. Use alligator clips and a grounding cord to attach any metal part of the device you are working on to the grounded workbench mat. 6 Introduction and Safety