TÜV SÜD Product Service 3 Description of the Equipment Under Test Description of the Equipment Under Test Product: Beats Wireless Model no.: 810-00012-00 Brand Name: Beats Options and accessories: NIL Rating: 3.7VDC (supplied by Battery) (or supplied by USB port of PC via USB cable) RF Transmission Frequency: 2402-2480MHz Antenna Gain: 0dBi Description of the EUT: NIL Auxiliary Equipment Used during Test: DESCRIPTION | MANUFACTURER | MODEL NO.(SHIELD) | S/N(LENGTH) NoteBook | Lenovo | XC200 | --- Report Number: 68.920.12.002.01 Page 4 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299

A white test report page with a TÜV SÜD Product Service logo at top right, a gray section header bar, a two-column specification list, and a small auxiliary equipment table at the middle.

Reading notes: Table model number XC200 and header labels are small and read clearly but are part of a technical table rather than advertising copy. Footer address and contact lines are small fine print; digits were read as printed.

Printed product names
Beats Wireless · NoteBook · Lenovo
Languages
English
PDF page 1

Report Number: 68.920.12.002.01 Page 1 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 FCC- TEST REPORT Report Number : 6 8 . 92 0 . 1 2 . 0 02 .0 1 Date of Issue: 22 March 2012 Model : 810-00012-00, 810-00012-01 Product Type : Beats Wireless Applicant : Beats Electronics, LLC Address : 1601 Cloverfield Blvd. Suite 5000N Santa Monica, CA 90404 United States Production Facility : Charter Media (Dongguan) Co., Ltd. Address : Daibandi Industrial Zone, Daning District, Humen Town, Dongguan City, Guangdong Province 523930, P. R. China Test Result :  Positive  Negative Total pages including Appendices : 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. Jiangsu TÜV Product Service Ltd. – Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. Jiangsu TÜV Product Service Ltd. – Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from Jiangsu TÜV Product Service Ltd. – Shenzhen Branch issued reports. This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval

Reading notes: Transcript is intentionally empty because the exact text is preserved separately; the fields were filled only from the supplied extracted copy and not verified against a visible image. 'Beats Wireless' appears as a Product Type on a certification report, not as advertised copy, so it was not listed under productNames. The report number is printed with irregular spacing (6 8 . 92 0 . 1 2 . 0 02 .0 1) and was not normalized. No headline, advertised prices, or advertising claims appear in the supplied copy.

Printed dates
22 March 2012
Languages
English
PDF page 2

Report Number: 68.920.12.002.01 Page 2 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 1 Table of Contents 1 Table of Contents…………………………………………………………………….............. 2 2 Details about the Test Laboratory…………………………………………………………… 3 3 Description of the Equipment Under Test………...………………………………….…….. 4 4 Summary of Test Standards…………………...………………………………………….…. 5 5 Summary of Test Results….…………………...……………………………………………. 6 6 General Remarks……………………………………………………………………………... 7 7 Technical Requirements……………………………………………………………………… 8 7.1 Conducted Emission AC Power Port…………………………………….……….…. 8 7.2 Conducted Peak Power………………………………………………………………. 12 7.3 Band edge compliance of RF emission………………………………….……..…... 14 7.4 Spurious RF Conducted emission…………………………………………….…..… 28 7.5 Spurious radiated emissions…………………………………………………….…… 36 7.6 20dB Bandwidth……………………………………………………………………….. 40 7.7 Carrier Frequency Separation…………………………………………………..…… 48 7.8 Number of Hopping Frequencies ………………………………………………….... 51 7.9 Dwell Time…………………………………………………………………………..…. 54 8 System Measurement Uncertainty…………………………………………………….…… 65

Reading notes: Supplied copy is a Jiangsu TÜV Product Service test report contents page, not an advertisement, so no advertised products or prices apply. Report Number 68.920.12.002.01 and section numbers are not treated as printed dates. Page layout and reading order were inferred only from the supplied copy, not from a visual image.

Languages
English
PDF page 3

Report Number: 68.920.12.002.01 Page 3 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 2 Details about the Test Laboratory Details about the Test Laboratory Location 1: Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6th Floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District 518048, Shenzhen,P.R.C. Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299 Location 2 : Audix Technology (shenzhen) Co.,Ltd Block Shenzhen, Science & Industry Park, Nantou, Shenzhen, Guangdong, China Telephone: 86 755 2663 9496 Fax: 86 755 2663 2877

Reading notes: Headline not clearly identifiable; no primary heading is printed in the supplied copy. Report number 68.920.12.002.01 is listed as printed but may be a reference number rather than a date.

Printed dates
68.920.12.002.01
Languages
English
PDF page 4

Report Number: 68.920.12.002.01 Page 4 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 3 Description of the Equipment Under Test Description of the Equipment Under Test Product: Beats Wireless Model no.: 810-00012-00 Brand Name: Beats Options and accessories: NIL Rating: 3.7VDC (supplied by Battery) (or supplied by USB port of PC via USB cable) RF Transmission Frequency: 2402-2480MHz Antenna Gain: 0dBi Description of the EUT: NIL Auxiliary Equipment Used during Test: DESCRIPTION MANUFACTURER MODEL NO.(SHIELD) S/N(LENGTH) N oteBook Lenovo XC200 ---

Printed product names
Beats Wireless
Languages
English
PDF page 5

Report Number: 68.920.12.002.01 Page 5 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 4 Summary of Test Standards Test Standards FCC Part 15 Subpart C, 10-1-2010 Edition PART 15 - RADIO FREQUENCY DEVICES Subpart C - Intentional Radiators

Printed dates
10-1-2010
Languages
English
PDF page 6

Report Number: 68.920.12.002.01 Page 6 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 5 Summary of Test Results Technical Requirements FCC Part 15 Subpart C Test Condition Pages Test Result Test Location Pass Fail N/A 15.207 Conducted Emission AC Power Port 8 Location 2 15.247 (b) (1) Conducted peak output power 12 Location 2 15.247(d) Band edge compliance of RF emissions 14 Location 2 15.247(d) Spurious RF conducted emissions 28 Location 2 15.247(d) 15.209 Spurious radiated emissions 36 Location 2 15.247(a)(1) 20dB bandwidth 40 Location 2 15.247(a)(1) Carrier frequency separation 48 Location 2 15.247(a)(1)(iii) Number of hopping frequencies 51 Location 2 15.247(a)(1)(iii) Dwell Time 54 Location 2

Reading notes: Report number 68.920.12.002.01 is printed on the page header and may be a document identifier rather than a date

Printed dates
68.920.12.002.01
Languages
English
PDF page 7

Report Number: 68.920.12.002.01 Page 7 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 6 General Remarks Remarks This submittal(s) (test report) is intended for FCC ID: COW81000012 complies with Section 15.207, 15.209, 15.247 of the FCC Part 15, Subpart C Rules. The two models 810-00012-00 and 810-00012-01 are identical only except the enclosure color, 810-00012-00 is black color, 810-00012-01 is white color, so all the RF tests were applied on 810-00012-00, 810-00012-01 is deemed to fulfill relevant RF requirement without further testing. All the configurations of the product were tested and only the worst test results are listed in the report. SUMMARY: All tests according to the regulations cited on page 5 were  - Performed  - Not Performed The Equipment Under Test  - Fulfills the general approval requirements.  - Does not fulfill the general approval requirements. Sample Received Date: 13 December 2011 Testing Start Date: 14 December 2011 Testing End Date: 16 March 2012 - Jiangsu TÜV Product Service Ltd. – Shenzhen Branch - Reviewed by: Prepared by: Tested by: _______________________ _______________________ _______________________ Ken Li Cookies Bu Leo Li EMC Project Manager EMC Project Engineer EMC Test Engineer

Reading notes: Headline is not clearly identifiable in the supplied copy; set to null.

Printed product names
810-00012-00 · 810-00012-01
Printed dates
13 December 2011 · 14 December 2011 · 16 March 2012
Languages
English
PDF page 8

Report Number: 68.920.12.002.01 Page 8 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 7 Technical Requirement 7.1 Conducted Emission Test Method 1 The EUT was placed on a table, which is 0.8m above ground plane 2 The power line of the EUT is connected to the AC mains through a Artificial Mains Network (A.M.N.). 3 Maximum procedure was performed to ensure EUT compliance 4 A EMI test receiver is used to test the emissions from both sides of AC line Limit Frequency QP Limit AV Limit MHz dBμV dBμV 0.150-0.500 66-56* 56-46* 0.500-5 56 46 5-30 60 50 Decreasing linearly with logarithm of the frequency Remark: This test was carried out in all the test modes, here only the worst test result was shown.

Reading notes: Report number 68.920.12.002.01 may be an identifier rather than a date; listed only as printed

Printed dates
68.920.12.002.01
Languages
English
PDF page 9

Report Number: 68.920.12.002.01 Page 9 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Conducted Emission

Reading notes: No primary heading is clearly identifiable; 'Conducted Emission' appears as a section label rather than a headline.

Languages
English
PDF page 10

Report Number: 68.920.12.002.01 Page 10 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Conducted Emission

Languages
English
PDF page 11

Report Number: 68.920.12.002.01 Page 11 of 65 Jiangsu TÜV Product Service Ltd. – Shenzhen Branch 6 floor, H Hall, Century Craftwork Culture Square, No. 4001, Fuqiang Road, Futian District, Shenzhen 518048, P. R. China, Tel. +86 755 8828 6998, Fax: +86 755 8828 5299 Test Equipment List DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE Test Receiver Rohde & Schwarz ESCS30 100162 May 29, 2012 L.I.S.N. Rohde & Schwarz ENV216 101161 May 29, 2012 50Ω Coaxial Switch Anritsu MP59B 6100214550 N/A Voltage Probe Rohde & Schwarz TK9416 N/A May 29, 2012 I.S.N Teseq GmbH ISN T800 30327 May 29, 2012 LCL adaoter Teseq GmbH ADT800- Cat.5 30327.01 May 29, 2012 LCL adaoter Teseq GmbH ADT800- Cat.3 30327.02 May 29, 2012 LCL adaoter Teseq GmbH ADT800-R 30327.02 May 29, 2012

Reading notes: Model 'ADT800-Cat.5' and 'ADT800-Cat.3' are printed across line breaks and may be split by hyphenation Manufacturer and model columns are tabular; row association inferred from layout order

Printed product names
Test Receiver · L.I.S.N. · 50Ω Coaxial Switch · Voltage Probe · I.S.N · LCL adaoter · ADT800-Cat.5 · ADT800-Cat.3 · ADT800-R
Printed dates
May 29, 2012 · N/A
Languages
English