### PDF page 12

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-d68ae9591bbbe74ae4dbad824d4dd33f0224506f6dacc791c15c221c4067cb2f)

Quad-Core Intel Xeon Processors

Transcribed text:

1  Technology Overview
Xserve
Quad-Core Intel
Xeon Processors
Inside every Xserve are one or two powerful new Quad-Core Intel Xeon 5400 series
processors running at up to 3.0GHz. Informally known during development as
“Harpertown,” these second-generation quad-core processors are built with Intel’s
state-of-the-art 45-nm process using the enhanced Intel Core microarchitecture.
Combining high performance in a power-efficient design, the Xeon 5400 series
processors help make the new Xserve the most powerful Apple server ever.
Enhanced Intel Core Microarchitecture
The Xeon 5400 series introduces an enhanced Core   microarchitecture   featuring larger
on-die caches, improved power management, and a new instruction set. The result
is a second-generation quad-core processor that delivers superior performance and
energy efficiency to a broad range of 32-bit and 64-bit applications and services.
These   enhancements   represent another milestone in Intel’s continuous development
of next-generation silicon processes and processor architecture. A wide range of
applications will benefit, including web and application servers, database servers,
scientific applications, graphics processing, and video encoding.
12MB On-Die L2 Cache
The Intel Xeon 5400 series processor features a large 12MB level 2 cache, configured
as two 6MB banks of Advanced Smart Cache. The larger L2 cache, a key processor sub-
system aided by the 45-nm process size, increases the efficiency of the processing cores
by reducing memory access latency and keeping more data closer to the processor.
Intel’s Advanced Smart Cache is a multicore-optimized cache. It improves performance
and efficiency by increasing the probability that each execution core of a multicore pro-
cessor can access data from a higher-performance, more efficient cache subsystem. To
accomplish this, the Quad-Core Intel Xeon processor shares 6MB of L2 cache between
cores. Unlike most multicore implementations, which leave each execution core to store
data in its own L2 cache, Advanced Smart Cache optimizes cache resources by storing
data in a single place that each core can access. By sharing L2 caches among multiple
cores, the Intel Advanced Smart Cache also allows each core to dynamically utilize up
to 100 percent of available L2 cache—6MB in the case of the Xeon 5400 series. When
one core has minimal cache requirements, other cores can increase their percentage of
L2 cache, reducing cache misses and increasing performance.
Key features
•   Enhanced Intel Core microarchitecture
•   12MB on-die L2 cache
•   Dual independent 1600MHz system buses
•   Reduced idle power
•   High-performance floating-point division
•   Enhanced 128-bit SSE4 SIMD engine
•   Mac OS X Server v10.5 Leopard

Reading notes: Heading reads 'Technology Overview' above 'Xserve' and 'Quad-Core Intel Xeon Processors'; primary heading taken as the Xeon title.

Printed product names: Xserve · Xeon 5400 · Harpertown · Mac OS X Server v10.5 Leopard

Languages: English

[Original PDF page 12](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=12)

### PDF page 13

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-65f8197ab9290ebc8430f544f7d68754ced56c9f38fc0306fa7c1be3a498bcb4)

Transcribed text:

1  Technology Overview
Xserve
Dual Independent System Buses
A faster 1600MHz system bus complements the Xeon 5400 microarchitecture.
Dual independent buses, one per processor, support a wide and fast path to system
memory—ideal for intense computing environments, 32-bit and 64-bit business-
critical applications, and robust server platforms.
Reduced Idle Power
The Xeon processors in the new Xserve consume a maximum of 80W per processor,
providing more computation capability in the same thermal profile as the previous-
generation Xserve—for a tremendous boost in performance-per-watt. In addition,
the Xeon 5400 series processor has enhanced power management features that, in
conjunction with the power management of Mac OS X Server, reduce the idle power
to as low as 4W. Spread across the typical daily workload of an Xserve, lower idle
power can greatly reduce average server power consumption, lowering both power
and cooling bills.
High-Performance Floating-Point Division
The Xeon 5400 series processor implements a new radix 16 divider that nearly doubles
the speed of floating-point division over the previous-generation Xeon, improving the
performance of scientific, 3D, and other mathematically intensive workloads.
Enhanced 128-Bit SSE4 SIMD Engine
SIMD (single instruction, multiple data) processing accelerates data manipulation by
simultaneously applying a single instruction to multiple pieces of data. The Quad-Core
Intel Xeon processor incorporates an enhanced 128-bit Streaming SIMD Extensions
(SSE) vector engine. Supporting SSE2 and SSE3 instructions, the Xeon 5400 series
adds SSE4 extensions that incorporate 47 new instructions tailored for media and
high-performance computing applications.
Also new to the Xeon 5400 series processor is the Super Shuffle Engine—a 128-bit-wide
single-pass shuffle unit that can perform full-width byte shuffles in a single cycle.
Similar to the vector permute instruction in the Velocity Engine of the PowerPC, the
Super Shuffle Engine can boost performance for numerous data movement operations,
including pack, unpack, and shifts used in algorithms such as image analysis, video
compression and decompression, data analysis, and high-performance computing.
Mac OS X Server and multiple cores
Mac OS X Server v10.5 features improved pro-
cessor scheduling, thread management, and
affinity algorithms to take advantage of the
latest generation of multicore Intel processors.

Reading notes: Heading 'Technology Overview' is a section title; no separate primary headline is clearly printed

Printed product names: Xserve · Xeon 5400 · Mac OS X Server · Mac OS X Server v10.5 · Quad-Core Intel Xeon · Super Shuffle Engine · Velocity Engine · PowerPC

Languages: English

[Original PDF page 13](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=13)

### PDF page 14

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-bcbda981475f57dbafc6b162205a1cff3d26b14f1714e74a139c15a08e926847)

Xserve High-Bandwidth Server Architecture

Transcribed text:

14 Technology Overview
Xserve
High-Bandwidth
Server Architecture
The Quad-Core Intel Xeon processor is only part of the Xserve performance story
Dual independent frontside buses keep data moving in and out of each processor,
and a super-efficient system controller keeps data moving between all subsystems.
Bandwidth is further enhanced by a 256-bit-wide memory controller and a PCI
Express 2.0 I/O architecture. Together, these advanced technologies provide the
performance and throughput for demanding Internet applications, robust network
infrastructure solutions, and high-performance computational clustering environments.
Server-Optimized Architecture
One or two Quad-Core Intel Xeon processors.   Deliver
industry-leading performance in a power-efficient design.
Dual independent 1600MHz frontside buses.   Complement
the quad-core processors by providing a wide and fast path
to system memory.
 56-bit-wide memory controller with 800MHz DDR    ECC
FB-DIMM memory.   Provides up to 25.6GB/s bandwidth and
up to 32GB capacity.
High-performance SATA/SAS storage controller.   Supports
SATA drives or—for the most demanding applications—
15,000-rpm SAS drives. Delivers up to 3Gb/s of storage
performance per channel and up to 3TB of hot-plug internal
storage. 1
Dual PCI Express    .0 expansion.   Supports two indepen-
dent PCI Express 2.0 expansion slots—one eight-lane and
one 16-lane—for bandwidth of 4GB/s or 8GB/s; the 8x slot
can be configured to support a PCI-X card.
Dual onboard Gigabit Ethernet.   Provides two independent
ports as well as hardware support for VLAN tagging, jumbo
frames, and TCP, IP, and UDP hardware checksum.
1

4

6
5
1
   

4
5
6

Reading notes: Callout numbers and feature markers appear in the copy without clear association to specific features. The 'PCI Express    .0' heading has a damaged or missing character. Memory controller width is printed as '56-bit' in one bullet, which may be a damaged '256-bit' reading.

Printed product names: Xserve · Quad-Core Intel Xeon · PCI Express 2.0 · PCI-X

Languages: English

[Original PDF page 14](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=14)

### PDF page 15

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-b719be6971a842c175cc9c8d855dbc94dbff64cabeac437be63abef59a2790c9)

Transcribed text:

15 Technology Overview
Xserve
Dual Independent 1600MHz Frontside Buses
Xserve features dual independent 64-bit frontside buses—one bus per processor—to
support a wide and fast path to system memory. The parity-protected buses feature a
unique power-saving capability that powers down part of the bus when full bandwidth
is not being utilized. Each channel runs at 1600MHz independent of processor speed;
combined, they provide up to 25.6GB/s bandwidth.
Advanced FB-DIMM Memory Technology
The fully buffered DIMM (FB-DIMM) is the next evolution in memory technology for
servers and workstations that value both capacity and bandwidth. With older memory
technologies, as signaling rates increase, the number of DIMMs supported per channel
decreases. The result has been a trade-off between overall memory capacity and band-
width. FB-DIMMs evade this trade-off by providing maximum capacity at the highest
bandwidth.
The FB-DIMM is based on a high-speed point-to-point interface that uses an Advanced
Memory Buffer (AMB) between the memory module and the memory controller. With
high-speed serial communications, the number of wires needed to connect the chipset
to the memory module is significantly lower. FB-DIMM memory channels require just
69 pins from the memory controller, compared with 240 pins for traditional parallel DDR2
memory. This efficiency allows more memory channels from the memory controller,
increasing memory performance.
Previous memory technologies used a shared parallel interface with all DIMMs on the
same bus. The AMB decouples the memory interface from the DRAM components,
allowing the memory bus to run at high speed with more DIMMs. This also allows
simultaneous reads and writes using industry-standard DDR2 DRAM chips.
The comparison of FB-DIMM communications to parallel memory communications
is similar to the comparison of PCI Express communications to PCI or PCI-X parallel
communications. PCI Express and FB-DIMMs use high-speed serial interfaces for com-
munications and feature a reduced pin count and higher signaling rates. Both provide
separate channels for data transmission and data reception, supporting simultaneous
read and write operations. Both also provide higher bandwidth than their predecessors,
use fewer communications lines (pins), take less space on the main logic board, and
result in significantly greater system flexibility and increased capability for the end user.
Quad-channel    56-bit-wide memory controller
Xserve incorporates a new 256-bit-wide memory controller that allows for higher speed,
greater capacity, and improved reliability. Using fast 800MHz DDR2 FB-DIMM memory
gives an immediate boost to application performance. When sets of four matched
DIMMs are installed in Xserve, the memory controller utilizes all four memory channels
for synchronized 256-bit memory transactions, further increasing performance.
Memory capacity up to    GB
Xserve provides memory capacity up to 32GB for the most demanding applications and
data sets.
Advanced error protection
FB-DIMM technology offers higher reliability and better availability and serviceability.
That includes powerful, enhanced data ECC protection, such as single-bit error correc-
tion and detection of multiple-bit errors. It also includes various other complementary
high-availability features, such as ECC on-demand scrubbing, CRC on all transactions,
SDDC algorithms to detect and correct a single device failure, and on-DIMM embedded
diagnostics.
What is a fully buffered DIMM?
A fully buffered DIMM, or FB-DIMM, is a
new kind of high-performance computer
memory module that helps increase a
system’s reliability, speed, and memory
density while keeping down costs. Based
on a high-speed point-to-point interface,
it works with an Advanced Memory Buffer
ASIC that allows full-speed, simultaneous
reads and writes using industry-standard
DRAM chips.
4GB DIMM support
Xserve supports 4GB DIMMs, allowing the
system to accommodate up to 32GB of
main memory.

Reading notes: Memory capacity figure 'up to GB' appears with a missing numeral in the source copy.

Printed product names: Xserve

Languages: English

[Original PDF page 15](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=15)

### PDF page 16

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-71ccb4e1b5143799a2f64f587205cfbe3553dcc4e27e12c012d21a607f3919de)

Transcribed text:

16 Technology Overview
Xserve
•   Error Correction Code protection with on-demand scrubbing.   ECC automatically
detects a single-bit error when read from main memory and detects (but doesn’t
correct) multiple-bit errors. When a cache line is read from main memory and a single-
bit ECC error is detected, the memory controller will trigger an interrupt and log the
error (including the DIMM number, which remote monitoring tools will also display),
while automatically correcting it and passing its data along to the processor cache.
As part of the correction process, a hardware memory scrubber immediately rewrites
the value to correct the memory error in main memory. This feature prevents any
future read of the same memory location from taking an ECC interrupt and impacting
performance, while also trying to prevent a single-bit error from degenerating into a
multiple-bit error.
•   Enhanced CRC (cyclic redundancy checking) protection.   CRC checks the transfer
of all addresses, commands, and data, and automatically retries the transaction when
an error is detected, assuring uninterrupted operation in case of transient errors.
Without the advanced error detection capabilities of FB-DIMMs, errors such as this
would normally halt the system.
•   Single Device Data Correction (SDDC).   For even higher memory availability, the
memory controller in Xserve implements an advanced error detection and correction
algorithm called Single Device Data Correction (SDDC), which detects and automatically
corrects the failure of a single x4 or x8 memory DRAM on a fully buffered DIMM. It also
supports detection of a two-wire fault on the DIMM connector or main logic board.
•   On-DIMM embedded diagnostics.   The Advanced Memory Buffer (AMB) ASIC on every
FB-DIMM contains embedded diagnostics features, including error detection, error
injection, and Built-In Self-Test (BIST). The features do not provide error protection during
system runtime; rather they allow for extensive and quick diagnostics during system
Power-On Self-Test (POST), during hardware testing with diagnostics software, and
during factory testing and system qualification. These capabilities help ensure that
system memory does not suffer from any hard failures in the AMB or DRAM components,
or from any communications problems between the FB-DIMM and memory controller.
High-Performance PCI Express Expansion
Xserve features PCI Express 2.0 expansion slots with up to four times the bandwidth of
the previous generation—ideal for connecting to high-performance networking, storage,
cluster interconnect, graphics, and backup devices using optional expansion cards. Two
independent PCI Express 2.0 slots provide 4GB/s or 8GB/s of bandwidth each. Slot 1 can
be configured to support a PCI-X expansion card through an optional expansion riser,
preserving customer investments in expensive or custom cards and devices. An easy-
access riser with captive screws makes installing or removing expansion cards quick and
easy, while increasing strength and support for larger cards.
Technology   Length support   Power
Slot 1   x8 PCI Express 2.0   6.6 inches   25 watts
(with PCI Express riser)   (16.76 cm)
133MHz PCI-X
(with optional PCI-X riser)
Slot 2   x16 PCI Express 2.0   9.25 inches   25 watts
(with PCI Express riser)   (23.49 cm)
Apple offers a wide range of expansion cards for Xserve, including Dual- and Quad-
Channel 4Gb Fibre Channel PCI Express, Ultra320 SCSI PCI-X, and Dual-Channel Gigabit
Ethernet PCI Express Cards.
Maximizing memory performance
Using four memory channels and
256-bit-wide memory architecture, Xserve
can achieve bandwidth up to 25.6GB/s.
For the best system performance, memory
should be installed in sets of four identical
FB-DIMMs.

Reading notes: Table column alignment for slot specifications may be ambiguous in reading order

Printed product names: Xserve · Fibre Channel PCI Express · Ultra320 SCSI PCI-X · Dual-Channel Gigabit Ethernet PCI Express Cards · FB-DIMM · PCI Express 2.0 · Advanced Memory Buffer

Languages: English

[Original PDF page 16](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=16)

### PDF page 17

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-1b839457a39352239cd8c275c9694329b9563fc0d003ecd6bcd6b4828f42488e)

Transcribed text:

17 Technology Overview
Xserve
Industry-Standard Connectivity
Dual onboard Gigabit Ethernet
Apple extends the networking performance of Xserve with a high-performance
Ethernet controller integrated into the I/O chipset. This advanced controller includes
two independent 10/100/1000BASE-T Ethernet interfaces, each configurable for
independent networks or teamed with 802.3ad link aggregation built into Mac OS X
Server. The result is tremendous networking bandwidth and no contention for data
with the I/O subsystems.
In addition, the Gigabit Ethernet controller provides these networking features:
•   Hardware-generated TCP, IP, and UDP checksum detects packet corruption and
transmission errors.
•   802.1q VLAN (virtual LAN) tags allow Xserve to be a member of multiple virtual
networks and to provide unique network services to each one.
•   A 48Kb buffer supports jumbo frames, or packets up to 9KB, to reduce system
overhead and increase throughput of all network activities.
Dual Gigabit Ethernet ports deliver near-line-rate throughput of up to 980Mb/s
per port, alleviating bottlenecks even with very large files, and expediting mail, web,
file-sharing, and printer-sharing services. Together with the multihoming function in
Mac OS X Server, dual network ports enable Xserve to serve more client systems; pro-
vide redundant links; support a dedicated metadata network for Xsan; and support
an isolated management network that is independent of a client services network.
Internal graphics
Administrators often need a quick way to plug in a display to access their servers. The
base configuration of Xserve now offers built-in graphics, no longer requiring an addi-
tional card in a valuable expansion slot. The built-in graphics controller provides 64MB
of RAM and applications, and takes advantage of its 2D/3D graphics acceleration to
enhance rendering and video processing. A mini-DVI output makes it possible to drive
up to a 23-inch Apple Cinema HD Display, and a mini-DVI to VGA adapter is included
for connection to standard VGA devices and KVM (keyboard-video-mouse) switches.
Additional connectivity
Xserve offers industry-standard interfaces for a range of connecting I/O devices:
•   Dual FireWire 800 ports.   Two FireWire 800 ports on the back panel connect to
high-bandwidth FireWire (IEEE 1394) devices, such as storage devices and audio
and video input devices. In addition, TCP/IP over FireWire can be used to create
small clusters or an IP failover back-channel network, while FireWire target disk
mode allows easy data migration and cloning of system configurations.
•   DB-9 serial port.   An industry-standard 9-pin serial port allows for system access
through a serial console session.
•   Three USB    .0 ports.   Two USB 2.0 ports on the back panel and one on the front
connect to keyboards, mice, speakers, and other industry-standard peripheral devices.
•   Optical drive.   For software installation and recovery, an 8x double-layer-burning
SuperDrive (DVD+R DL/DVD±RW/CD-RW) is standard, permitting data archival and
backup to DVD-R and DVD+R DL media.
Dual power supplies
Hot-swappable and load-sharing, the
redundant power supply option for Xserve
provides greatly enhanced reliability. The
power supplies are also easily serviceable
in case of failure.

Printed product names: Xserve · Mac OS X Server · Xsan · Apple Cinema HD Display · SuperDrive

Languages: English

[Original PDF page 17](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=17)

### PDF page 18

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-01e37f368879ce12602fb2b8aef6f3b82f2ffc51e8f1a1721573941bf5e80e46)

Transcribed text:

18 Technology Overview
Xserve
Flexible Storage Options
Large databases, digital video footage, immense scientific data sets, and uncom-
pressed video all place enormous demands on server storage resources. Addressing
these growing requirements by providing an industry-leading capacity of up to 3TB
of affordable internal storage, 1  Xserve offers characteristic storage performance and
flexibility with three drive bays accepting hot-plug Apple Drive Modules. The new
Xserve continues to offer both SATA (Serial ATA) drive support—upgraded to include
the latest SATA hard drives with increased performance, capacity, and value—as
well as SAS (Serial Attached SCSI) hard drives for the highest performance and most
demanding applications. The optional Xserve RAID card adds internal hardware RAID
0, 1, and 5 to the three drive bays in Xserve.
With each Apple Drive Module on an independent drive channel and connected to
a 3Gb/s SATA/SAS storage controller, the Xserve storage subsystem scales without
compromising performance. This unique architecture delivers the best balance of
performance, reliability, capacity, and price.
SATA Drive Technology
Xserve makes significant advances in built-in server storage with features such as a
sophisticated 3Gb/s SATA/SAS storage controller with a dedicated bus to each Apple
Drive Module. Xserve continues to deliver incredible internal storage capacity and
value, now supporting up to 3TB using new 7200-rpm 1TB Apple Drive Modules that
employ state-of-the-art perpendicular recording technology.
Every SATA drive in Xserve is rated 24/7 server class for reliability and performance.
The independent drive architecture in Xserve isolates the drives electrically, preventing
a single drive failure from causing unavailability or performance degradation of the
surviving drives—a common problem with multidrive parallel SCSI implementations.
The end result is a storage architecture that provides tremendous throughput and
excellent storage scalability.
SAS Drive Technology
Serial Attached SCSI storage, the next generation of SCSI technology, is designed for
the most demanding storage applications. Providing higher sequential performance—
over 125MB/s with 3.5-ms seek time—and far higher random performance than SATA
drives, the SAS capabilities are nothing short of phenomenal. 4
The 15,000-rpm Apple SAS drives provide the highest storage performance available
today. Rated enterprise class, they have best-in-class MTBF (mean time between
failures) ratings. That means you can trust Xserve to deliver ultimate reliability for
critical server environments and applications such as email and database serving.
0 to 1TB with perpendicular recording
The “bits” that constitute data have typically
been recorded end to end, or longitudinally
in a single plane on the surface of a hard
drive’s recording platter. The 1TB SATA drives
offered with Xserve use state-of-the-art
perpendicular recording technology to stack
the bits vertically and in multiple planes,
thereby achieving much greater capacity in
a given area. Xserve accommodates three
such drive modules to provide an astounding
amount of internal storage—up to 3TB—in a
1U form factor.

Reading notes: Superscript-style note markers (1, 4, 0) appear inline and may be footnote or caption artifacts. Sidebar text on perpendicular recording is positioned separately, so reading order relative to the main body is uncertain.

Printed product names: Xserve · Xserve RAID card · Apple Drive Module · Apple SAS drives

Languages: English

[Original PDF page 18](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=18)

### PDF page 19

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-f7e163aaf845b37cb60d13b35eb8437bc49fb5d48f5575dcff8af8423a0abf7d)

Transcribed text:

19 Technology Overview
Xserve
Because SAS has the same physical interface as SATA and leverages the hot-plug
Apple Drive Module carrier, Xserve users can make a per-bay choice between the
SATA or SAS drive. This unusual degree of flexibility means that Xserve can be
configured for a broader range of applications and specific requirements, making
the platform a better long-term choice for corporations and data centers.
Apple Drive Modules
In Xserve, the three 3.5-inch hard drive bays support greater internal capacity and
more flexible RAID options than offered by other servers in the same class. Apple
Drive Modules are affordable and simple to add. Choose 80GB or 1TB SATA Apple
Drive Modules running at 7200 rpm, or 73GB or 300GB SAS Apple Drive Modules
running at 15,000 rpm. 1
Robust hot-plug connectors in Apple Drive Modules protect the connecting pins from
bending when drives are inserted or removed. Hot plugging allows administrators to
add storage without bringing down the server. Insert a new Apple Drive Module at
any time and it’s instantly available to the server. This convenience is made possible
by tight integration between system hardware and software.
Apple Drive Modules feature a unique handle design for fast and easy installation;
a positive locking mechanism holds them tightly in place after insertion. The drive
carrier employs a drive mounting technique that increases drive isolation and reduces
vibration, especially important for high-performance 15,000-rpm drives. Carefully
tested and qualified to ensure maximum performance and superior reliability, Apple
Drive Modules work seamlessly with the sophisticated Xserve monitoring sensors and
Server Monitor remote monitoring software.
Monitoring of drive health
Xserve hardware and software work together to provide industry-leading remote
monitoring and alert capabilities. The server operating system reads Self-Monitoring,
Analysis, and Reporting Technology (SMART) data from each hard drive. SMART data
allows the drive to report its health and enables Server Monitor software to warn
the administrator of a prefailure condition—providing the opportunity to back up
critical data and replace the hard drive before a failure occurs. For local monitoring,
each Apple Drive Module has two LEDs, one for drive activity and one for drive health.
Software and Hardware RAID Options
Affordable and easy-to-install drive modules make it simple to expand Xserve systems
to meet growing storage needs over time. For even greater storage capacity or to
share storage among multiple servers, high-throughput PCI Express 2.0 slots enable
users to connect to external rackmount storage and backup systems, including Fibre
Channel and SCSI devices.
Software RAID in Mac OS X Server
Using software RAID built into Mac OS X Server, the three Apple Drive Modules can
be striped or mirrored for improved performance or data redundancy.
•   RAID 0, or striping.   Increases storage performance dramatically by distributing data
across two or three Apple Drive Modules and enabling the drives to read and write
data concurrently. Drive striping takes full advantage of the three independent drive
channels and utilizes the I/O capabilities of Mac OS X Server.
•   RAID 1, or mirroring.   Provides a high level of data protection by creating a real-time,
exact duplicate of the contents of one Apple Drive Module on a second drive. With
the volume promotion feature in Mac OS X Server, you can upgrade a single drive to a
Apple Drive Modules
Xserve uses reliable, easy-to-install, high-
performance Apple Drive Modules to provide
cost-effective, high-capacity system storage.

Reading notes: Text ends mid-sentence at RAID 1 bullet, so the final sentence may be truncated. Footnote marker '1' appears after drive specifications without its referent visible.

Printed product names: Xserve · Apple Drive Module · Mac OS X Server · Server Monitor

Languages: English

[Original PDF page 19](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=19)

### PDF page 20

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-ae325a39d0bc3172ae93d375ae664ebadb7f16d36da3fb5f165c1afe347e2842)

Transcribed text:

 0 Technology Overview
Xserve
RAID 1 mirror without needing to reformat the drive and reinstall the operating system.
If a mirrored drive fails, the system can rebuild the array in the background, while con-
tinuing to serve data. The independent drive architecture and software RAID combine
to provide RAID 1 protection with no performance penalty.
For additional protection or higher performance, Mac OS X Server can boot from a
mirrored or striped volume.
Xserve RAID card
For the ultimate in data protection, add the optional Xserve RAID card to Xserve. With
256MB of RAID cache and hardware RAID levels 0, 1, and 5, the Xserve RAID card delivers
up to 251MB/s RAID 5 performance for the most demanding server workloads 4 —without
taking up a valuable PCI Express expansion slot. With a built-in battery that protects the
RAID cache for up to 72 hours, your data is further protected from unexpected power
outages. The easy-to-use RAID Utility software provides a graphical interface to set up,
manage, and maintain your internal hardware RAID volumes.
Fibre Channel
Fibre Channel is the most sensible and reliable networking choice for any organization
or business with growing data storage needs. Ideal for server applications, it has become
the industry’s de facto fast-switching system standard for moving highly scalable volumes
of data at multi-gigabit speeds between computers, servers, disk arrays, and other devices.
In addition, Fibre Channel is the only storage connectivity technology available today
that guarantees bandwidth as well as in-order delivery of data packets—key require-
ments for streaming media such as video.
Xserve supports Apple’s Dual- or Quad-Channel 4Gb Fibre Channel PCI Express Cards,
providing a high-speed storage interface with a dedicated bandwidth and throughput
of up to 400MB/s per channel. Fibre Channel supports multiple topologies, further
increasing storage options with Xserve. When used with the included SFP-to-SFP cables
in a point-to-point configuration, Fibre Channel can directly connect external Fibre
Channel storage at up to 400MB/s per channel.
Adding a Fibre Channel switch allows multiple Fibre Channel storage subsystems to
be connected to a single Xserve, or multiple Xserve systems to be connected to one or
more Fibre Channel storage subsystems—creating a simple storage area network (SAN).
The addition of Apple’s Xsan software results in a shared storage architecture that sup-
ports large, flexible storage pools with multiple servers and workstations sharing access
to the same volumes and files.
Apple 4Gb Fibre Channel PCI Express Cards
The Dual- and Quad-Channel 4Gb Fibre Channel PCI Express Cards offer dedicated
bandwidth with a throughput of up to 400MB/s per channel. Fibre Channel interconnect
technology supports multiple application environments, using point-to-point, loop, and
fabric topologies. Each card comes with a 2.9-meter (9.5-foot) SFP-to-SFP 4Gb active
copper cable per channel.
Xsan
Xsan is a 64-bit cluster file system designed for both small and large computing envi-
ronments that demand the highest level of data availability. This specialized technology
enables multiple Xserve systems, as well as Mac Pro workstations, to share RAID storage
volumes over a high-speed Fibre Channel network. Each client can read and write directly
to the centralized file system, scaling storage bandwidth while improving workgroup
collaboration.
Internal hardware RAID
The Xserve RAID card provides internal
hardware RAID supporting RAID 0, 1, and 5
with 256MB of cache and a 72-hour cache
battery backup.
Apple 4Gb Fibre Channel PCI Express Cards
Use the Apple Dual- or Quad-Channel 4Gb
Fibre Channel PCI Express Card to connect
to an Xsan network and high-performance
external storage systems.

Reading notes: Footnote marker '4' appears after the RAID 5 performance claim without a visible footnote text in the supplied copy.

Printed product names: Xserve · Xserve RAID card · Mac OS X Server · Apple's Dual- or Quad-Channel 4Gb Fibre Channel PCI Express Cards · Xsan · Mac Pro

Languages: English

[Original PDF page 20](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=20)

### PDF page 21

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-81a12bcc6f58021226d6f5a779e09dee3a5190f6b3a4ab163d77f57cf36b0f44)

Transcribed text:

 1 Technology Overview
Xserve
Enterprise-class features—such as metadata controller failover, Fibre Channel
multipathing, and built-in volume management—make Xsan an ideal choice for
storage consolidation and NAS replacement in data centers. Xsan is designed to
provide file-level locking with concurrent read and write access, volume sizes up
to 2 petabytes, and fine-grained permissions using access control lists (ACLs).
Such robust features allow Xsan to scale out file services for a large number of
users and to accelerate high-bandwidth workflows in film and video. In addition,
thanks to groundbreaking prices, Xsan meets the low-cost requirements of
computational clusters.
Whether in data centers, video post-production facilities, or high-performance
computing environments, Xsan delivers these important benefits:
•   Storage consolidation.   Pools data across multiple RAID arrays for better performance
and more efficient storage utilization.
•   High throughput.   Eliminates the bottlenecks of Ethernet-based networks.
•   Simultaneous read/write access.   Enables workgroups to collaborate easily and
accomplish results faster than ever with concurrent file access.
•   Easy volume scalability.   Plugs in more RAID devices as storage requirements
grow—expanding the shared volume easily.
•   Increased data availability.   Eliminates single points of failure through metadata
controller failover and Fibre Channel multipathing.
Xsan delivers all of this performance, flexibility, and scalability without the
complexity—or the cost—of competitive SAN solutions.

Printed product names: Xserve · Xsan

Languages: English

[Original PDF page 21](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=21)

### PDF page 22

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-e636cc6dbd276316ab84dd0209ca128640a04e69cc413274695dc3970f416e55)

Transcribed text:

 Technology Overview
Xserve
Integrated Lights-Out
Remote Management
Xserve includes built-in remote monitoring capabilities that enable network admin -
istrators to stay in touch with their Xserve systems from anywhere on the network
or over the Internet. Enabled by hardware built into every Xserve system, the remote
management system stays running as long as the system is plugged into power—
even if the system is powered off or in a hung state. Xserve monitoring and manage-
ment tools run securely over TCP/IP, using robust password authentication based on
an enhanced version of the Intelligent Platform Management Interface (IPMI). And
everything needed—hardware and software—is included with every Xserve, with no
further purchase required.
Anywhere, Anytime Monitoring and Control
Forget about ever again having to trek to the server rack to control your server. Built-in
lights-out management (LOM) capabilities allow remote control of an Xserve system
from anywhere on the network or over the Internet. Easy-to-use Server Monitor soft-
ware provides complete remote access to Xserve, including reboot, power on, and
power off. Remote Server Admin tools let you configure and monitor all key services
of Mac OS X Server from near or far. If you prefer using a terminal window, Server
Admin provides extensive command-line tools to configure, monitor, and manage
your systems remotely using the preinstalled secure shell (SSH).
Built on industry standards, Xserve lights-out management conforms to version 2.0 of
the IPMI specification, which will continue to improve server management and help
reduce costs—by enabling customers to save time, maximize IT resources, and poten-
tially manage multivendor environments in the same way. It also provides a highly
secure environment for protecting management data and server deployments from
unauthorized access.
Dedicated Monitoring Hardware
Embedded in the I/O controller of every Xserve main logic board is a dedicated
microcontroller. This independently powered, fully out-of-band LOM processor can
communicate directly to the host system or through the Ethernet channels in the I/O
controller—allowing administrators to talk to Xserve even if it’s powered off or has
crashed. The system need only be connected to power and the Ethernet network.
For data centers with a serial terminal server infrastructure, Xserve also provides
console access over built-in serial (DB-9) or Ethernet ports. And if network services
are down, UNIX-savvy administrators can access the system through a serial
console session.
Remote management
Built-in remote management features in
Xserve allow administrators to control and
monitor information on hundreds of Xserve
systems from any Internet-connected
Mac OS X system.

Reading notes: Printed version number '2.0' refers to the IPMI specification and is not a date Reading order of the 'Remote management' sidebar relative to body text is uncertain

Printed product names: Xserve · Mac OS X Server · Server Monitor · Server Admin

Printed dates: 2.0

Languages: English

[Original PDF page 22](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=22)

### PDF page 23

[Cite this scan](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/2#scan-016ff0d16e897f8079c03e966f6df4a2879ba626343a0b0aac574c06649f1805)

Transcribed text:

 Technology Overview
Xserve
More than 100 embedded hardware sensors in the Xserve enclosure integrate with
Apple’s sophisticated Server Monitor software to check the condition of critical
subsystems, such as memory, fans, power supplies, and Ethernet links. Temperature
measurements for hard drives, processors, memory, PCI, power supply, and incoming
ambient temperature are processed using a microcontroller and dedicated communi-
cations buses on the logic board.
Server Monitor Software
To maximize server uptime, Server Monitor software aids in the early identification
and easy diagnosis of system problems. This powerful application uses data from
the hardware sensors and the LOM processor to continuously report on the status
of all Xserve subsystems, for all servers on the network. If operating conditions for
any component exceed predefined thresholds, Server Monitor can instantly send
notification via email or email-capable pager, so network administrators can respond
quickly to prevent or repair the problem.
Server Monitor can monitor hundreds of servers using a single, intuitive interface.
Each server is identified by name and IP address (or DNS host name), and at-a-glance
summary information indicates the status of individual components (green indicates
OK, yellow means warning, red alerts of an error). A click on any icon displays detailed
status and performance information, including these individual server attributes,
subsystems, and system variables:
•   Info.   Lists key attributes of the server: name, IP address, device kind, operating system
version, processor type, amount of memory, firmware version, uptime, last monitoring
update, and hardware serial number.
•   Memory.   Displays the size, speed, and type of memory installed in each system, as
well as ECC error counts.
•   Drives.   Provides the status of each of the server’s hard drives, including SMART
data for predictive failure notification. Hardware or software RAID information is
also available.
•   Power.   Shows the current, voltage, and processor power, as well as a historical line
graph for each supply rail. Also provides uninterruptible power supply (UPS) informa-
tion and status when available.
Automatic notifications
Server Monitor can send an email to alert
specified individuals when operating
conditions exceed predefined thresholds.
Short text messages can be sent to email-
capable pagers, cell phones, or PDAs;
full-text details can be sent to email clients
or full-function PDAs.

Printed product names: Xserve · Server Monitor

Languages: English

[Original PDF page 23](https://www.vintageapple.net/files/d82d2ebf941e5256c011aac1f839c3c6a07c29e557e8c399be3ae5d299753d83/Xserve_TO_20080108.pdf#page=23)

[Previous transcribed scans](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/1.md)

[Next transcribed scans](https://www.vintageapple.net/transcripts/media/apple-original-fb7f8e4820318c38/3.md)