PDF page 10

Submitted to Studies in Conservation, March 2006 4 pixels that were adjacent to either red or to blue pixels. For the three-plane image, only the red, blue, and red-adjacent green pixels were used. The physical movement of the two filters resulted in a registration difference between the pair of three-plane images, typically on the order of ten pixels (about 0.25%). Using the public domain software library, ITK [7], and assuming that the images varied only in translation, the images were registered by applying a transformation calculated from a small user-defined region of the image. (A more robust approach is a future activity.) A multiplicative spatial correction was applied to compensate for spatially non-uniform lighting, commonly used to accentuate surface topography such as impasto. The correction was based on an image of a neutral background, shot under the same conditions as the object. A transformation matrix was derived from a calibration target of known spectral reflectance factors. The transformation matrix was used to convert the six-channel image to a 36- channel image, resulting in an estimate of the object’s spectral reflectance factor as a function of position. The calibration procedure is described in the next section. For most applications, the spectral image was rendered for a specific CIE illuminant and observer using conventional colorimetric calculations. For the case of an ICC color-managed workflow, this was CIE Illuminant D50 and the 1931 standard observer. The rendering produced a digital master saved as a 16-bit CIELAB TIFF file with linear encoding with respect to CIELAB (similar to reciprocal gamma encoding of 1/2.4). For archiving purposes, we anticipate storing the registered spatially-corrected six- channel images along with corresponding calibration meta-data using the DNG file format. Technical Approach – Details The multi-filter approach [8] was first demonstrated using an IBM Pro/3000 digital camera based on a monochrome linear CCD with colorimetric filters. For the current Kodak KAF 22000CE

Reading notes: Source is a technical manuscript excerpt with no primary heading; headline set to null Reading order of the excerpt begins mid-sentence and includes a section heading 'Technical Approach – Details' that may not be a primary heading

Printed dates
March 2006
Languages
English
PDF page 11

Submitted to Studies in Conservation, March 2006 5 CCD sensor, filters had to be defined and fabricated. An optimization was performed to select filters from among the Schott filter glass catalog. The optimization considered spectral and colorimetric accuracy, image noise, capture time, and fabrication simplicity and cost [9 – 11]. There were a number of different filter pairs with similar performance. We selected a pair in which one of the filters resulted in spectral sensitivities similar to the sensor with its original blue-green cover glass. Thus, the camera could also be used in the usual fashion as a color- managed RGB digital camera. The final filters are listed in Table 1 and plotted in Figure 2. Each was a “sandwich” of an absorption filter and a visible bandpass filter (i.e., a UV and NIR blocking filter). The bandpass filter transmitted radiation between 380 and 750 nm. The surface of each filter facing the sensor was anti-reflection coated to minimize inter-reflections between the lens filter and CCD cover glass. The spectral sensitivities of the CFA sensor are plotted in Figure 3. In the visible region, there are the expected three peaks at red, green, and blue wavelengths. The red channel has sensitivity in the red and near infrared regions while the blue and green channels have sensitivity in the near infrared. The effect of placing each optimized filter in the optical path is plotted in Figure 4. The blue-green filter predominantly affects the red channel sensitivity by defining the wavelength of peak sensitivity and bandwidth. The yellow filter predominantly affects the blue channel sensitivity by narrowing bandwidth. The visible bandpass filter, common to both filter sandwiches, limits spectral sensitivity to the visible region, critical when correlating with the human visual system. Based on Figure 4, it appears that the two filters have a minimal affect on increasing spectral information beyond that normally captured with a CFA sensor. As described above, spectral reflectance factor is estimated by a linear calibration transformation. This is equivalent to creating new spectral sensitivities by weighted addition or subtraction of the spectral sensitivities plotted in Figure 4. As an example, in Figure 5, the yellow-filtered blue channel was subtracted from the blue-green-filtered blue channel and blue-green filtered red channel was subtracted from the yellow-filtered red channel, plotted as dashed lines, along with the blue-green filtered spectral sensitivities, plotted as solid lines. It is observed that the visible spectrum is sampled in five discrete locations. The two-filter approach along with the calibration transformation has enabled the increase in sampling number. Typically, the matrix coefficients are optimized to minimize either spectral or colorimetric error. We have developed a technique where both errors were minimized [12],

Reading notes: Header line reads 'Submitted to Studies in Conservation, March 2006' and page number '5' appears; no primary heading identified. Passage begins mid-document, so reading order relative to earlier pages is uncertain.

Printed dates
March 2006
Languages
English
PDF page 12

Submitted to Studies in Conservation, March 2006 6 based on the Wyszecki hypothesis that a stimulus can be decomposed into a fundamental stimulus and a metameric black [13]. Our approach was similar to the Fairman technique of transforming a parameric pair into a metameric pair [14]. Conceptually, the fundamental stimulus corresponds to the spectral information that our visual system processes. The metameric black corresponds to the spectral information that is not processed; hence it has no color and it is black. The metameric black defines the spectral characteristics that depend on the specific colorants used to provide selective absorption. Accurate estimation of a fundamental stimulus results in high colorimetric accuracy. Accurate estimation of a metameric black results in high spectral accuracy. Previously [12], the colorimetric transformation consisted of a nonlinear stage that accounted for stray light, differences in geometry between the reference spectrophotometer and camera system, and any non-linearities in the camera signal processing. Experimentally, the transfer functions were nearly linear with a small offset. This allowed the transformation to be simplified as shown in Eqs. (1) – (5): M pinv = R Reference pinv D Reference ( ) (1) A = 100 ! S y diag S ( ) xyz (2) T ! E 00 = f NonLinOpt ( R Reference , A , D Reference ), where T ! E 00 minimizes ! E 00 ( T ! E 00 D , " A R Reference ) # $ % & (3) M ! E 00 = A " A A ( ) # 1 T ! E 00 + I # A " A A ( ) # 1 " A ( ) M pinv (4) ˆ R ! E 00 = M ! E 00 D (5) where n is the number of wavelengths, i is the number of camera channels, and j is the number of reference color patches. Matrix M pinv is a [ n × ( i+ 1)] transformation matrix from digital counts to spectral reflectance factor computed from R Reference, a [ n × j ] matrix containing the calibration target reference spectrophotometric measurements ranging from zero to unity and DReference is an [( i+1 ) × j ] camera digital count matrix with the last row set to unity (homogenous coordinates). The operation pinv represents the Moore-Penrose singular-value decomposition-based pseudoinverse function in Matlab [6]. Matrix A is a [ n × 3] matrix of tristimulus weights

Reading notes: Equation text in the source is garbled and partly unreadable, so the mathematical notation is not reliably recoverable.

Printed dates
March 2006
Languages
English
PDF page 13

Submitted to Studies in Conservation, March 2006 7 computed from S , a [ n × 1] vector of the spectral power distribution of the reference light source, y , a [ n × 1] vector of the reference luminance color matching function, and xyz , a [n × 3] matrix of the reference color matching functions. Matrix T ! E 00 is a [ 3 × ( i+ 1)] transformation matrix from digital counts to tristimulus values fit using nonlinear optimization described below. Matrix M ! E 00 [ n × ( i+ 1)] is a transformation matrix from digital counts to spectral reflectance factor computed from A , T ! E 00 , I , an [ n × n ] identity matrix, and M ! E 00 . Vector ˆ R ! E 00 [ n × 1 ] is the imaging-based estimated spectral reflectance factors; it is the product of M ! E 00 and D , a [( i+ 1) × 1] vector of camera digital counts with the last element set to unity. In Eq. (3), T ! E 00 was optimized using a two stage process. First, nonlinear constrained optimization was used to minimize the average ∆ E00 compared with the reference tristimulus values using a starting value for T ! E 00 of ! A R Reference pinv( D Reference ) . These optimized matrix coefficients were used as starting values for a second nonlinear constrained optimization that minimized (Mean( Δ E00)/Mean( Δ E00)Optimization 1+ max( Δ E00)/max( Δ E00) Optimization 1). Both optimizations were subject to the constraint that the coefficients not change more than ±50% from their starting values. In Eq. (4), the left-most term of the right-hand side of the equation, A ! A A ( ) " 1 T # E 00 , estimated the fundamental stimulus and the right-most term, I ! A " A A ( ) ! 1 " A ( ) M pinv , estimated the metameric black. The final linear calibration transformation is shown in Eq. (5). As a linear operation, it was implemented very efficiently. Experimental Verification – Targets The MCSL-Sinar system was tested in the Imaging Department of the National Gallery of Art, Washington DC (NGA). It was compared with two other systems. The first was our spectral measurement system consisting of a Quantix monochrome sensor coupled with a Cambridge Research Institute liquid crystal tunable filter (LCTF), evaluated at NGA previously [2, 15]. The system used diffuse tungsten illumination. The calibration transformation was based on a GretagMacbeth ColorChecker DC and a custom target of blue acrylic artist paints, described below. The second system was a stock Sinarback 54M with a P3 body and a 100mm lens with

Reading notes: Equation symbols and matrix notation are garbled in the extracted text, so mathematical expressions are unreliable. Several characters within equations appear damaged or misencoded.

Printed product names
GretagMacbeth ColorChecker DC · Quantix · Sinarback 54M · Cambridge Research Institute liquid crystal tunable filter
Printed dates
March 2006
Languages
English
PDF page 14

Submitted to Studies in Conservation, March 2006 8 integral shutter. This system was used routinely at NGA. The calibration target was a GretagMacbeth ColorChecker SG. Commercial software was used to create an ICC camera profile for the NGA system. The MCSL-Sinar and NGA-Sinar systems used the identical lighting set-up, a pair of Broncolor Xenon strobes, positioned at approximately a 70° angle from the surface normal on either side of the artwork. One side had about twice the irradiance. This resulted in a quite collimated, raking illumination. For this experiment, four targets were evaluated, described in Table 2. The GretagMacbeth targets were available commercially. The Gamblin target was produced by mixing each of the 31 conservation colors with titanium white at two different concentrations and applying them to canvas board using a brush. The Blues target was made by mixing Liquitex Artist Acrylic ultramarine, cobalt, Prussian, and phthalocyanine blue paints and titanium white in various proportions in order to create a target with a large range of spectral characteristics. These paints were also applied to a canvas board using a brush. The experiment consisted of imaging the four targets followed by processing as described in Figure 1 and Eqs. (1) – (5). The targets were used as either calibration or verification targets. The colorimetric performance of the three systems is shown in Table 3. Both ∆ E00 and ∆ E*ab are shown, the former metric having better correlation with subjective evaluations of adjacent uniform color fields [16] and the latter having better correlation with images [17]. Experientially, the 90 th percentile results are a better indicator of performance than the maximum error, particularly for actual experiments (rather than computational analyses). The Best Case corresponds to the MCSL-Sinar system where the same target was used for calibration and verification. This provides a sense of the best mean performance that can be achieved using the MCSL-Sinar system and the linear signal processing workflow as described. These results are excellent indicating that the multi-filter system is capable of high color accuracy. The small differences in performance between matched calibration and verification targets (Best Case) and independent calibration and verification targets (MCSL-Sinar) indicate that the choice of calibration target is important. Although progress has been made [18, 19],

Reading notes: Text is a partial excerpt; the document ends mid-sentence. Table references (Table 2, Table 3) and figure/equation references are not reproduced in the supplied copy.

Printed product names
GretagMacbeth ColorChecker SG · Broncolor Xenon strobes · Liquitex Artist Acrylic · Gamblin target
Printed dates
March 2006
Languages
English
PDF page 15

Submitted to Studies in Conservation, March 2006 9 research is still required to develop an improved calibration target for imaging paintings. Guiding principles should include those defined for exemplifying color-order systems [20]. The color management at NGA was very good. The listed results are typical of a well color-managed area-array color sensor camera system [21, 22]. The modifications to the Sinar camera resulted in marked improvement, particularly for the Gamblin target that consisted of typical artist pigments used in paintings. There was nearly a threefold improvement, though some of this improvement may be attributed to the Blues calibration target, which better represents blue artist materials than the ColorChecker SG. An analysis of variance followed by a multiple comparison test based on Turkey simultaneous confidence intervals using the studentized range distribution was performed [6] on the CIEDE2000 values to assess statistical significance. For all the targets, the MCSL-Sinar system was superior to the NGA system at an α of 0.01. On average, the MCSL-Sinar system had slightly superior colorimetric performance to the Quantix-LCTF system. For the ColorChecker DC and Gamblin targets, the MCSL-Sinar system was superior at an α of 0.01. For the ColorChecker and Blues targets, the two systems were not significantly different. This is an important result: A six-channel camera had the average colorimetric accuracy of a 31-channel camera. The maximum and 90 th percentile errors for the Quantix-LCTF system were smaller for the Blue Pigments and Gamblin Conservation Colors targets. The improved average colorimetric performance was a result of the more complex signal processing combining colorimetric and spectral optimization. The colorimetric optimization used nonlinear optimization since color differences are nonlinearly related to incident radiation. This nonlinear optimization was impractical for the Quantix-LCTF since 250,000 independent data points were used to estimate 1,116 coefficients (31 x 36 matrix). Nonlinear optimization would have been extremely time consuming and convergence to a global minimum highly problematic. Therefore, the Quantix-LCTF calibration only optimized spectral- estimation accuracy using linear optimization. The spectral performance of the Quantix-LCTF and MCSL-Sinar systems are listed in Table 4. A metameric index was calculated to provide a performance metric in color-difference

Reading notes: 'Turkey' likely printed for 'Tukey' in the multiple comparison test reference Source contains a truncated sentence at the end ('color-difference') where reading continues beyond the excerpt

Printed product names
ColorChecker SG · ColorChecker DC · Gamblin · Blues · Quantix-LCTF · MCSL-Sinar · Sinar
Printed dates
March 2006
Languages
English
PDF page 16

Submitted to Studies in Conservation, March 2006 10 units. This index is a ∆ E00 value for CIE Illuminant A following a slight spectral adjustment [14] such that for CIE Illuminant D65, the colorimetric data are identical, that is, a ∆ E00 of zero. [The spectral adjustment is the Fairman parameric correction, shown in Eq. (4).] The spectral root- mean-square (RMS) error over the wavelength range of 380-730 nm was also calculated. The Quantix-LCTF system had higher spectral accuracy than the MCSL-Sinar system. For the ColorChecker DC, the ColorChecker, and the Blues targets, the Quantix-LCTF system was superior at an α of 0.01 (based on evaluating RMS error); for the Gamblin target, there was not a statistically significant difference. The superior performance was the expected result since the Quantix-LCTF system was a true spectral device whereas the MCSL-Sinar was an abridged device. What was unexpected was that the performance of the MCSL-Sinar system was so close to the Quantix-LCTF system and for the Gamblin target, the two systems were equivalent statistically. Furthermore, the Best Case results and the Quantix-LCTF system were not significantly different except for the Blues target. To be fair, it needs to be pointed out that much more effort had been put into development of the MCSL-Sinar system. Once we achieved an acceptable result for the spectral camera, we began looking at more practical approaches. It is likely that if we had selected the Quantix-LCTF system as the recommended system, better performance would be reported herein. The GretagMacbeth ColorChecker Color Rendition Chart has become a de facto imaging standard. The spectral estimation accuracy of this target for the MCSL-Sinar and Quantix-LCTF systems are shown in Figure 6. The average spectral difference as a function of wavelength is plotted as the blue solid line. The Quantix-LCTF system had a nearly flat curve quite close to zero, the desired result whereas the MCSL-Sinar system had a strong undulation. Plots of the neutral colors would show excessive undulation. This is a common result for such an abridged spectrometer. We have performed some preliminary research to address this problem including pigment mapping [23] and treating the camera system as a conventional spectrophotometer [24]. At every wavelength, a scatter plot could be made comparing the spectrophotometer and camera system and a line fit to these data. A correlation coefficient of the line fit would indicate the amount of scatter. In order to have a number with similar magnitude to the spectral differences, the correlation coefficient, ranging between zero and unity, was subtracted from

Reading notes: Excerpt begins mid-document and the primary heading is not present in the supplied text Some mathematical symbols and bracketed editorial insertions may not reflect exact printed form

Printed product names
GretagMacbeth ColorChecker Color Rendition Chart
Printed dates
March 2006
Languages
English
PDF page 17

Submitted to Studies in Conservation, March 2006 11 unity. Perfect correlation would yield zero. These values as a function of wavelength are plotted in Figure 6 as the dashed red line. For both systems, large scatter occurred for short wavelengths. This was caused largely by the calibration targets containing titanium dioxide white. It has very low reflectance in this wavelength range and the spectral variation of the target patches was very small. This resulted in large uncertainty when estimating these wavelengths using each camera system. A second reason concerned the low quantum efficiency of CCD sensors in this wavelength range, also increasing uncertainty. Experimental Verification – Henri Matisse, Pot of Geraniums When the Quantix-LCTF system was tested at NGA, three paintings were imaged: Alvise Vivarini, Saint Jerome Reading ; Alexej von Jawlensky, Murnau ; and Henri Matisse, Pot of Geraniums ; all among the permanent collection of NGA. The Matisse proved to be the most challenging [2, 15], having the widest range of pigments and spectral properties. This painting was again imaged using the MCSL-Sinar and NGA-Sinar systems. A GretagMacbeth EyeOne had been used to measure 43 positions on the painting. The painting and the measurement positions are shown in reference 2. Preliminary evaluations were performed where each test target was used to derive the calibration transformation converting camera signals to spectral reflectance factor and CIELAB for the MCSL-Sinar system. As described above, the results were affected by the choice of calibration target. Not surprising, the Gamblin target was the most successful. There were two reasons. First, the spectral properties of this target span the spectral properties of the painting. Second, this target was painted on canvas board, resulting in similar surface characteristics to the painting. Because the NGA lighting was so directional, having similar surface properties between the calibration target and the painting helped improve spectral and colorimetric accuracy. This second reason was more important than the first, as evinced by the Gamblin target having superior performance to the combination of the ColorChecker DC and Blues targets. The National Gallery of Art’s imaging workflow included visual editing where local and global color corrections were made using Adobe Photoshop to improve the color-matching accuracy between a work of art illuminated with high color rendering daylight-fluorescent

Reading notes: Reading order of the excerpt is partially discontinuous at the start (begins mid-sentence).

Printed product names
GretagMacbeth EyeOne · Adobe Photoshop · ColorChecker DC · Gamblin
Printed dates
March 2006
Languages
English
PDF page 18

Submitted to Studies in Conservation, March 2006 12 sources (nominal CCT of 5000 K) and the image rendered on a color-managed CRT display [3]. Their digital master image files included these visual adjustments. The colorimetric accuracy of Pot of Geraniums is summarized in Table 5. The Quantix- LCTF system had the best colorimetric performance on average, likely a result of using diffuse rather than directional illumination. This underscores how lighting for aesthetic purposes may not result in optimal images for scientific purposes. The MCSL-Sinar system had slightly lower average accuracy than the Quantix-LCTF system. Given the aesthetic-oriented lighting, this was an excellent result. The color-managed NGA-Sinar system image before visual editing also had good performance given its intrinsic limitations as a three-channel RGB device. Statistically, these three systems were not significantly different from one another. The uncertainty in comparing in-situ measurements with spectral imaging increased variability [2] compared with color targets; consequently, the performance differences were not statistically significant. A disappointing, although common [21, 22], result was that the visual editing decreased accuracy dramatically. Average ∆ E00 increased by over 50%. This digital master was statistically significantly worse than the other three images at an α of 0.01. Some of the possible reasons for the increased error might have been a poorly color-managed display, unmatched white points in terms of chromaticity and luminance resulting in light and chromatic adaptation differences between the viewing illuminant and display, differences in lighting geometry between the imaging system (directional Xenon strobe) and the viewing environment (overhead fluorescent daylight), differences in image size, and observer metamerism. The color changes were reductions in chroma and lightness. The spectral performance is shown in Table 6 and Figures 7 and 8. The MCSL-Sinar system had reasonable performance, well capturing the spectral characteristics of the painting throughout the majority of the sampled spectrum. Similar to the ColorChecker results, both systems had poor performance at short wavelengths, as seen in Figure 8. The average RMS difference as a function of wavelength was centered about zero for the MCSL-Sinar systen whereas for the Quantix-LCTF system, there was a systematic under-prediction in spectral reflectance factor. This was a result of geometric differences between the camera taking

Reading notes: Text begins mid-document with a partial page header; reading order may be incomplete. Spelling 'systen' appears to be a typographical error in the source.

Printed dates
March 2006
Languages
English
PDF page 19

Submitted to Studies in Conservation, March 2006 13 illumination geometry, the calibration target spectrophotometric measurement geometry, and differences in gloss between the calibration targets and the painting. An interesting result was that the correlation spectra were similar in shape for both systems. The spectral performances were not statistically significantly different. Conclusions A practical spectral-based imaging system has been developed in which a color filter array (CFA) digital camera was combined with two absorption filters. By taking two sequential images, one with each filter, and deriving a linear transformation matrix using a target of colored patches with reference spectral reflectance factor values, spectral images were estimated. The performance was evaluated for test targets and an oil painting, Henri Matisse’s Pot of Geraniums . This system had spectral and colorimetric performance that was equivalent to a true spectral imaging system consisting of a monochrome camera and liquid-crystal tunable filter. The main advantage of this new system is that any CFA professional-grade camera system can be used, following a simple modification of replacing the detector cover glass and the addition of a filter slider, or wheel, or holder (i.e., changing filters manually). This means that scientific imaging of the visible spectrum can be the responsibility of an imaging department rather than a highly specialized instrument requiring a conservation scientist well versed in color and imaging science. Because the system does not have a permanent infrared cut-off filter, it can also be used for infrared reflectometry; the CFA has spectral sensitivity over a wavelength range similar to IR film. Using an appropriate visible-spectrum cut-off or bandpass filter, the camera can be used as a conventional RGB camera, a spectral camera, or an NIR camera. Future research will focus on imaging and spectrophotometric geometry considerations, improving the spectral accuracy for neutral samples, an improved calibration target, and an Adobe Photoshop implementation of the Matlab software.

Reading notes: Source appears to be a journal article excerpt with no primary heading; headline set to null Page-number and running-header line ordering at the top of the excerpt may not reflect the original reading order

Printed dates
March 2006
Languages
English
PDF page 20

Submitted to Studies in Conservation, March 2006 14 Acknowledgements The authors would like to thank the National Gallery of Art, Washington, D.C., the Museum of Modern Art, New York, the Andrew W. Mellon Foundation, and the Institute of Museum and Library Services for their financial support of the Art Spectral Imaging (Art-SI) Project. We also acknowledge the assistance of the Division of Imaging and Photographic Services and the Division of Conservation at the National Gallery of Art. References 1 Berns, R.S., ‘Color accurate image archives using spectral imaging’, in Scientific Examination of Art: Modern Techniques in Conservation and Analysis, National Academy Press, Washington, (2005) 105- 119. 2 Berns, R.S., Taplin, L.A., Imai, F.H., Day, E.A., Day, D.C., ‘A Comparison of Small-Aperture and Image-Based Spectrophotometry of Paintings’, Studies in Conservation 50 (2005) 1- 14. 3 Berns, R.S. and Taplin, L.A., ‘Evaluation of a Modified Sinar 54M Digital Camera at the National Gallery of Art’, MCSL Technical Report, http://art-si.org/ (2005). 4 Imai, F.H., Berns, R. S., and Tzeng, D., ‘A comparative analysis of spectral reflectance estimation in various spaces using a trichromatic camera system’, Journal of Imaging Science and Technol ogy 44 (2000) 280- 287. 5 Taplin, L.A. and Berns, R.S., ‘Practical spectral capture systems for museum imaging’, in 10 th Congress of the International Colour Association, 8- 13, May 2005 , Granada (2005) 1287- 1290. 6 Mathworks, MATLAB [CD-ROM], Ver 7.1, [Computer Program], The Mathworks Inc., Natick, MA (2005). 7 Ibáñez, L., The ITK Software Guide, 2 nd edn, Kitware, Clifton Park (2003) 539. 8 Imai, F.H., ‘Multi-spectral image acquisition and spectral reconstruction using a trichromatic digital camera system associated with absorption filters’, MCSL Technical Report, http://www.cis.rit.edu/mcsl/research/CameraReports.shtml (1998). 9 Berns, R.S., Taplin, L.A., Nezamabadi, M., and Zhao, Y., ‘Modifications of a Sinarback 54 Digital Camera for Spectral and High-Accuracy Colorimetric Imaging: Simulations and Experiments’, MCSL Technical Report, http://art-si.org/ (2004).

Reading notes: Reference 1 page range and publication details are split across lines, possibly affecting reading order.

Printed dates
March 2006 · 2005 · 2003 · 2004 · 1998 · 2000
Languages
English
PDF page 21

Submitted to Studies in Conservation, March 2006 15 10 Zhao, Y., Taplin, L.A., Nezamabadi, M., and Berns, R.S., ‘Methods of Spectral Reflectance Reconstruction for A Sinarback 54 Digital Camera’, MCSL Technical Report, http://www.cis.rit.edu/mcsl/research (2004). 11 Berns, R.S., Taplin, L.A., Nezamabadi, M., Mohammadi, M., ‘Spectral imaging using a commercial color-filter array digital camera’, in ICOM Committee for Conservation 14 th Triennial Meeting, The Hague, 12- 16 September 2005 , Netherlands (2005) 743- 750. 12 Zhao, Y., Taplin, L.A., Nezamabadi, M., and Berns, R.S., ‘Using matrix R method for spectral image archives’, in 10 th Congress of the International Colour Association, 8- 13, May 2005 , Granada (2005) 469- 472. 13 Wyszecki, G., ‘Valenzmedtrische Untersuchung des Zusammenhanges zwischen normaler und anomaler Trichromasie’. (Psycholophysical investingation of the relationship between normal and abnormal trichromatic vision), Die Farbe 2 (1953) 39- 52 [in German]. 14 Fairman, H.S., ‘Metameric correction using parametric decomposition’, Color Research and Application 12 (1997) 261- 265. 15 Imai, F.H., Taplin, L.A., Day, D.C., Day, E.A., and Berns, R.S., ‘Imaging at the National Gallery of Art’, MCSL Technical Report, http://www.cis.rit.edu/mcsl/research (2002). 16 Melgosa, M., Huertas, R., Berns, R.S., ‘Relative significance of the terms in the CIEDE2000 and CIE94 color-difference formulas’, Journal of the Optical Society of America 21 , (A) (2004) 2269- 2275. 17 Stokes, M., Fairchild, M.D., and Berns, R.S., ‘Colorimetrically quantified tolerances for pictorial images’, in Technical Association of the Graphic Arts 2, (1992) 757- 778. 18 Mohammadi, M., Nezamabadi, M., Berns, R.S., Taplin, L.A., ‘A prototype calibration target for spectral imaging’, in 10 th Congress of the International Colour Association, 8- 13, May 2005 , Granada (2005) 387- 390. 19 Mohammadi, M., Nezamabadi, M., Berns, R.S., Taplin, L.A., ‘Spectral imaging target development based on hierarchical cluster analysis’, in IS&T/SID Twelfth Color Imaging Conference, 9- 12 November 2004, Scottsdale (2004) 59- 64. 20 McCamy, C.S., ‘Physical exemplifiction of color order systems’, Color Research and Application 10 (1985) 20- 25. 21 Murphy, E.P., A testing procedure to characterize color and spatial quality of digital cameras used to image cultural heritage , Master’s thesis, Rochester Institute of Technology (2005). 22 Smoyer, E.P., Taplin, L.A., Berns, R.S., ‘Experimental evaluation of museum case study digital camera systems’, in IS&T Second Image Archiving Conference , 26- 29 April 2005, Washington, D.C. (2005) 85- 90.

Reading notes: Bibliographic entry 13 contains a parenthetical English translation of a German title with a misspelling ('Valenzmedtrische', 'Psycholophysical', 'investingation'). Entry 20 contains spelling 'exemplifiction' as printed.

Printed dates
March 2006 · 2004 · 2005 · 2002 · 1997 · 1992 · 1985 · 1953 · 12- 16 September 2005 · 8- 13, May 2005 · 26- 29 April 2005 · 9- 12 November 2004
Languages